Improving Output Voltage of the Three Phase Six-Switch Inverters

Ebrahim Babaei, Mehdi Mahaei

Abstract


 In this paper, a simple method for selecting the best conductive angle based on power factor of load in three phase six-switch inverters is proposed. Conductive angle from 120º to 180º, and power factor from 0 to 1 are changed for lead and lag loads. Then RMS and THD values of the output voltage are studied. Simulation results show that a special conductive angle for each specific power factor has to be used to improve the mentioned indices and applying conventional conductive angles 120º, 180º and 150º in some power factors increases THD and decreases RMS of output voltage.


Full Text:

PDF

References


Guangqiang LV, Wang Q, Yanchao J. A Novel Induction Motor Soft Starter with Torque Pulsations Elimination Capability. IECON. N. Carolina, USA. 2005: 1695-1700.

Zenginobuz G, Cadirici I, Ermis M, Barlak C. Performance Optimization of Induction Motor During Voltage Controlled Soft Starting. IEEE Trans. Energy Convers. 2004; 19(2): 278-288.

Lai YS, Wang WK, Chen YC. Novel Switching Technique for Reducing the Speed Ripple of ac Drives with Direct Torque Control. IEEE Trans. Ind. Electron. 2004; 51(4): 768-775.

Jidin A, Sutikno T. Matlab/Simulink Based Analysis of Voltage Source Inverter with Space Vector Modulation. TELKOMNIKA Indonesian Journal of Electrical Engineering. 2009; 7(1): 23-30.

Sujanarko B, Ashari M, Purnomo MH. Improved Voltage of Cascaded Inverters Using Sine Quantization Progression. TELKOMNIKA Indonesian Journal of Electrical Engineering. 2010; 8(2): 123-130.

Tumbelaka HH, Borle LJ. Harmonic Mitigation Using a Polarized Ramp-time Current-Controlled Inverter. TELKOMNIKA Indonesian Journal of Electrical Engineering. 2010; 8(3): 235-244.

Iqbal A, Moinuddin S. Assessment of Torque Pulsation in Inverter Fed Three-Phase Induction Motor Drive for 180° and 150° Conduction Modes. International Conference on Information and Communication Technology in Electrical Sciences (ICTES). 2007: 323-328.

Saied MH, Mostafa MZ, Abdel-Moneim TM, Youse HA. On Three-Phase Six-Switch Voltage Source Inverters: A 150° Conduction Code. IEEE International Symposium on Industrial Electronics. 2006; 2: 1504-1509.

Helal AA, Saied MH. Dynamic Voltage Restorer Adopting 150° Conduction Angle VSI. IEEE Electric Power Conference (EPC). Canada. 2008: 1-6.




DOI: http://doi.org/10.12928/telkomnika.v9i3.741

Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

TELKOMNIKA Telecommunication, Computing, Electronics and Control
ISSN: 1693-6930, e-ISSN: 2302-9293
Universitas Ahmad Dahlan, 4th Campus
Jl. Ringroad Selatan, Kragilan, Tamanan, Banguntapan, Bantul, Yogyakarta, Indonesia 55191
Phone: +62 (274) 563515, 511830, 379418, 371120
Fax: +62 274 564604

View TELKOMNIKA Stats