Localizing Region-Based Level-set Contouring for Common Carotid Artery in Ultrasonography

Yong Chen, Xiao Ming Zhou, Dong C Liu

Abstract


 This work developed a fully-automated and efficient method for detecting contour of common carotid artery in the cross section view of two-dimensional B-mode sonography. First, we applied a preprocessing filter to the ultrasound image for the sake of reducing speckle. An adaptive initial contouring method was then performed to obtain the initial contour for level set segmentation. Finally, the localizing region-based level set segmentation automatically extracted the precise contours of common carotid artery. The proposed method evaluated 130 ultrasound images from three healthy volunteers and the segmentation results were compared to the boundaries outlined by an expert. Preliminary results showed that the method described here could identify the contour of common carotid artery with satisfactory accuracy in this dataset.


Full Text:

PDF

References


N.Denarie, J.Gariepy, G.Chironi, M.Massonneau, F.Laskri, J.Salomon, J.Levenson, and A.Simon, Distribution of ultrasonographically-assessed dimensions of common carotid arteries in healthy adults of both sexes. Atherosclerosis. 2000; 148: 297-302.

David C.Wang, Robert Klatzky, Bing Wu, Gregory Weller, Allan R.Sampson, and George D.Stetten, Fully Automated Common Carotid Artery and Internal Jugular Vein Identification and Tracking Using B-mode Ultrasound. IEEE Transactions on Biomedical Engineering. 2009; 56: 6.

Xin Yang, Jiaoying Jin, Mengling Xu, Huihui Wu, Wanji He, Ming Yuchi, and Mingyue Ding, Ultrasound Common Carotid Artery Segmentation Based on Active Shape Model, Computational and Mathematical Methods in Medicine. 2013; 2013, article ID 345968.

E.Ukwatta, J.Awad, A.D.Ward et al., Three-dimensional ultrasound of carotid atherosclerosis: semi-automated segmentation using a level set-based method. Medical Physics. 2011; 38(5): 2479-2493

A. Abdel-Dayem and M.El-Sakka, Carotid ultrasound image segmentation using Fuzzy region growing, Image Analysis and recognition. Springer, Berlin, Germany. 2005; 3656: 869-878.

Mao F, Gill J, Downey D, and Fenster A. Segmentation of carotid Artery in Ultrasound images, Engineering in Medicine and Biology Society 2000 Proceedings of the 22nd Annual International Conference of the IEEE. 2000; 3: 1734-1737

P.Abolmaesumi, M.Sirouspour, and S.Salcudean, real-time extraction of carotid artery contours from ultrasound images, proceedings of the 13th IEEE symposium on computer-based medical systems(CBMS’00), 2000; pp.181-186.

Shawn Lankton, Allen Tannebaum. Localizaing Region-Based Active Contours. IEEE Transactions on Image Processing. 2008; 17(11): 2029-2039.

Jaakko Astola, Petri Haavisto, and Yrjo Neuvo. Vector median filters. Proceedings of the IEEE. 1990; 79(4): 678-689.

Jaroslaw Krejza, Michal Arkuszewski, et al. Carotid Artery Diameter in Men and Women and the Relation to Body and Nect Size, Stroke. 2006; 37:1103-1105

Vikram Chalana, Yongmin Kim. A Methodology for Evaluation of Boundary Detection Algorithms on Medical Images. IEEE Transactions on Medical Imaging. 1997; 16(5): 658 - 660.




DOI: http://doi.org/10.12928/telkomnika.v11i4.1202

Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

TELKOMNIKA Telecommunication, Computing, Electronics and Control
ISSN: 1693-6930, e-ISSN: 2302-9293
Universitas Ahmad Dahlan, 4th Campus
Jl. Ringroad Selatan, Kragilan, Tamanan, Banguntapan, Bantul, Yogyakarta, Indonesia 55191
Phone: +62 (274) 563515, 511830, 379418, 371120
Fax: +62 274 564604

View TELKOMNIKA Stats