Squirrel cage induction motor scalar control constant V/F analysis

K. A. M. Annuar, M. R. Sapiee, Rozilawati M. Nor, M. S. M. Azali, M. B. N. Shah, Sahazati Md. Rozali

Abstract


In constant V/f control technique it is assume that the stator resistance and leakage inductance drops are negligible, especially at high speed and small load. In other words, the back emf is comparatively large at high speed and hence these voltage drops can be neglected. By maintaining constant V/f, constant Eg/f and hence constant air-gap flux is assumed. This assumption is however invalid at low speeds since a significant voltage drop appears across the stator impedance. The terminal voltage, V no longer approximates  ag. By using MATLAB Simulink, the open-loop constant V/f is simulated. It is shown that the performance of the drive deteriorates at low speeds. The improvement in the performance by applying voltage boost is shown and discussed.


Keywords


induction machine; induction motor; motor scalar control; open loop V/f control; slip compensation; squirrel cage;

Full Text:

PDF


DOI: http://doi.org/10.12928/telkomnika.v17i1.8818

Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

TELKOMNIKA Telecommunication, Computing, Electronics and Control
ISSN: 1693-6930, e-ISSN: 2302-9293
Universitas Ahmad Dahlan, 4th Campus
Jl. Ringroad Selatan, Kragilan, Tamanan, Banguntapan, Bantul, Yogyakarta, Indonesia 55191
Phone: +62 (274) 563515, 511830, 379418, 371120
Fax: +62 274 564604

View TELKOMNIKA Stats