PARAMETER OPTIMIZATION OF PITCH CONTROLLER FOR ROBUST FREQUENCY CONTROL IN AN ISOLATED WIND-DIESEL HYBRID POWER SYSTEM USING GENETIC ALGORITHM

Cuk Supriyadi Ali Nandar

Abstract


This paper focuses on the parameter optimization of the pitch controller for robust frequency control in an isolated wind-diesel hybrid power system. The structure of the pitch controller is a practical 1st–order lead-lag compensator. In system modeling, the normalized coprime factorization is applied to represent system uncertainties such as variations of system parameters etc. As a result, the robust stability of the controlled system against various uncertainties can be guaranteed. To obtain the controller parameters, the performance and stability conditions of H∞ loop shaping control are employed to formulate the optimization problem. The genetic algorithm is used to solve the problem. The frequency control effect and robustness of the proposed pitch controller against system uncertainties are evaluated by simulation studies in comparison with a variable structure pitch controller. 

Full Text:

PDF

References


. Ackermann, T., “Wind Power in Power Systems”, John Wiley & Sons, 2005.

. Hunter R.E.G., “Wind-diesel systems a guide to technology and its implementation”, Cambridge University Press, 1994.

. Lipman NH., “Wind-diesel and autonomous energy systems“, Elservier Science Publishers Ltd., 1989.

. Tripathy S.C., Kalantor, M. and Blalasubramanian, R., “Stability simulation and parameter optimisation of a hybrid wnd-diesel power generation system”, International Journal of Energy Research, vol.16, pp.31-37, 1992.

. Tripathy S.C., Kalantar, M. and Rao N.D., “Dynamic and stability of a wind stand-alone power system”, International Journal of Energy Conversion and Management, vol.34, pp.627-640, 1993.

. Bhatti T.S., Al-Ademi A.A.F. and Bansal N.K., “Dynamics and control of isolated winddiesel power systems”, International Journal of Energy Research, vol.9, pp.729-740, 1995.

. Bhatti T.S., Al-Ademi A.A.F. and Bansal N.K., “Load frequency control of isolated wind diesel hybrid power systems” International Journal of Energy Conversion and Management, vol. 39, pp. 829-837, 1997.

. Das, D., Aditya, S.K., and Kothari, D.P.” Dynamics of diesel and wind turbine generators on an isolated power system” International Journal of Elect Power & Energy Syst., vol. 21, pp.183-189, 1999.

. Sebastian, R. and Quesada, J.” Distributed control system for frequency control in a isolated wind system”, International Journal of Renewable Energy, vol.31, pp.285-305, 2006.

. Uhlen, K., Foss, B.A., and Gjosaeter, O.B., ”Robust control and analysis of a wind-diesel hybrid power plant”, IEEE Trans. on Energy Conv. Vol. 9, pp.701-708, 1994.

. Chedid, R., Mrad, F., and Basma, M., ”Intelligent Control of a class of controllers for wind energy conversion systems”, IEEE Trans. on Energy Conv., vol.14, pp.1597-1604, 1999.

. Macfarlane, D.C. and Glover, K., ”Robust controller design using normalized coprime factor plant descriptions”, Lecture notes in control and information sciences, Springer; 138, 1990.

. Skogestad, S. and Postlethwaite, ”Multivariable feedback control: analysis and design”, 2nd edition, John Wiely, 2005.

. Haupt, R.L. and Hault, S.E., ”Practical genetic algorithm”, 2nd edition, Wiley-interscience, 2004.




DOI: http://doi.org/10.12928/telkomnika.v6i3.562

Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

TELKOMNIKA Telecommunication, Computing, Electronics and Control
ISSN: 1693-6930, e-ISSN: 2302-9293
Universitas Ahmad Dahlan, 4th Campus
Jl. Ringroad Selatan, Kragilan, Tamanan, Banguntapan, Bantul, Yogyakarta, Indonesia 55191
Phone: +62 (274) 563515, 511830, 379418, 371120
Fax: +62 274 564604

View TELKOMNIKA Stats