Calibration of Geomagnetic and Soil Temperatur Sensor for Earthquake Early Warning System

Dodi Yudo Setyawan, Dona Yuliawati, Warsito Warsito, Warsono Warsono

Abstract


The study of Design of Earthquake Early Warning System for Real Time Using Geomagnetism and Total Electron Content with Fuzzy Logic through competitive grants scheme has obtained the prototype of the earthquake early warning system. However, it still needs improvements on in the calibration of thesensor system especially for MAG3110 sensor and DHT11 sensor. This calibration was done by adjusting the sensor system to the existing measuring devices standards in the Physics Department laboratory of the Sains Faculty Lampung University, to obtain measurement accuracyand to get a good result about where and when the earthquake would occurand how strong the earthquake would be. The calibration of MAG3110 sensor and DHT11 sensor obtained the standard correction results, the standard deviation of MAG3110 from 3 axes, namely x axis was 8.5, y axis was 2.66, and z axis was 1.9, whereas the standard deviation for DH11 sensor was 0.1161.


Keywords


calibration, earthquake, geomagnetism, total electron content, fuzzy logic

Full Text:

PDF


DOI: http://doi.org/10.12928/telkomnika.v16i5.7592

Refbacks



Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

TELKOMNIKA Telecommunication, Computing, Electronics and Control
ISSN: 1693-6930, e-ISSN: 2302-9293
Universitas Ahmad Dahlan, 4th Campus
Jl. Ringroad Selatan, Kragilan, Tamanan, Banguntapan, Bantul, Yogyakarta, Indonesia 55191
Phone: +62 (274) 563515, 511830, 379418, 371120
Fax: +62 274 564604

View TELKOMNIKA Stats