Accelerated Aging Effect on Epoxy-polysiloxane-Rice Husk Ash Polymeric Insulator Material
Abstract
Keywords
Full Text:
PDFReferences
Naidu M.S., Kamaraju V. High Voltage Engineering. New Delhi: Tata McGraw-Hill Publishing Company Limited. 1987
Looms, J.S.T. Insulator for High Voltage. London: Peter Pereginus Ltd. 1988.
Sorqvist T, Vlastos A.E. Performance and Ageing of Polymers Insulator. IEEE Trans. On Power Delivery. 1997;12(4):1657-1665.
Malik N.H., Al-Arainy A.A., and Quresshi M.I. Electrical Insulation in Power System. New York: Marcel Dekker Inc.1998.
Kahar N.Y. Penelitian Tentang Epoksi Sikloalifatik Tuang (EST) Sebagai Bahan Isolasi Listrik Tegangan Tinggi Di Daerah Beriklim Tropis. PhD Thesis, Postgraduate ITB,Bandung,1998.
Kaerner H.C., Schuetz A. The Dielectric Properties of Fibre Reinforced Epoxies under the Influence of Humidity. Proceeding of the 4th ICPADM., Brisbane. 1994.
Cherney E.A. Silicon Rubber Dielectrics Modified by Inorganic Fillers for Outdoor High Voltage Insulation Applications. IEEE Trans. On Dielectrics and Electrical Insulation. 2005; 12(6):1108-1115.
Berahim H. Metodologi Untuk Mengkaji Kinerja Isolasi Polimer Resin Epoksi Silane Sebagai Material Isolator Tegangan Tinggi di Daerah Tropis. PhD Thesis, Postgraduate UGM, Yogyakarta, 2005.
Houston D. F. Rice Chemistry and Technology. Minnesota: American Association of Cereal Chemist, Inc. 1972.
Onggo H. Proses Dan Sifat Campuran Abu Sekam Semen. Telaah, jilid IX, No.1. Bandung. 1986: 27-38..
Davis A., Sims D. Weathering of Polymers, First Edition. London: Applied Science Publisher Ltd. 1983.
Kind D, Kaerner H.C. High Voltage Insulation Technology. Braunschweig/Wiesbaden: Friedr Vieweg & Sohn.1985.
Vlastos A.E., Gubanski S.M. Surface structural changes of naturally aged silicone and EPDM composite insulators. IEEE Trans. On Power. Delivery. 1991; 6(2): 888-900.
Karady G.G., Shah M., Brown R.L. Flashover Mechanism of Silicon Rubber Insulators used for outdoor Insulation-I, IEEE Trans. on Pow. Delivery. 1995;10(4): 1965-1971.
Kim J., Chaudhury M.K., Owen M. J. Hydrophobicity Loss and Recovery of Silicone HV Insulation, IEEE Transaction on Dielectric and Electrical Insulation, 1999; 6(5): 695-702.
Sorqvist T., Karlson U., Vlastos A.E. Surface Ageing and its Impact on the Performance Insulators. Nint Intern. Symposium on High Voltage Engineering. Austria. 1995; 3234/1-3234/4.
Mizuno Y., Kusada H., Naito K. Effect of Climate Conditions on Contamination Flashover Voltage of Insulators.IEEE Trans. on Pow. Delivery. 1997; 10(3):1378-1383.
Obenaus F. Fremdschict Uberschlang Und Kreischweglange. Deutche Electrotechnik. 1985; (4);135-136.
IEC International Standard. 507-1991. Artificial Pollution Test on High-Voltage Insulator to be used on AC Systems. Geneva: CEI; 1991.
IEC International Standard 1109-1992. Composite Insulation for AC Overhead Lines with A Nominal Voltage Greater Than 1000 V-Definitions, Test Methode and Acceptance Criteria. Geneve: CEI; 1992.
IEC International Standard 601-1989. High Voltage Test Techniques. Geneva: CEI; 1989.
DOI: http://doi.org/10.12928/telkomnika.v10i4.853
Refbacks
- There are currently no refbacks.
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
TELKOMNIKA Telecommunication, Computing, Electronics and Control
ISSN: 1693-6930, e-ISSN: 2302-9293
Universitas Ahmad Dahlan, 4th Campus
Jl. Ringroad Selatan, Kragilan, Tamanan, Banguntapan, Bantul, Yogyakarta, Indonesia 55191
Phone: +62 (274) 563515, 511830, 379418, 371120
Fax: +62 274 564604